PQ Engineer Kit

PQ Engineer Kit

Save $1,544 off of $28,840 list price.
 

 

PQ Engineer Kit

Save $1,544 off of the combined list price of $28,840. E-MAIL for details.

Get equipped with the most durable and advanced system available for monitoring real, apparent and reactive power, RMS voltage and current, phase angle, power factor, harmonics and more.

Kit Contents

  • Vision Pro Handheld PQ Analyzer

  • Cell Revolution, with transient capture, 128MB memory, and Ethernet

  • Eagle 120 with Bluetooth and 8MB memory

  • FCT 4/12 Ultra Slim Four channel 100/1000/5000A flexible 12 in. CTs

  • FCT 4/24 Ultra Slim Four channel 100/1000/5000A flexible 24 in. CTs

  • TLAR 4 Four channel 20/200A iron-core CTs

  • Guardian wireless Bluetooth single-phase meter socket recorder

  • Cell Revolution Antenna Kit

  • Field PC ruggedized Windows Mobile PDA

  • Large Hard Carrying Case

  • Medium Hard Carrying Case

REVOLUTION®
INPUTSAC Voltage0 to 600 RMS continuous per phase
(±5 kV peak transients)
AC Current0 to 5000 Amps
Sample Rate1 MHz Voltage (16666 samples/cycle) 250 kHz current (4166 samples/cycle)
CHANNELSVoltage4 channels
Current4 channels
MEASURED
QUANTITIES
PER CYCLE
RMS VoltageVolts
RMS CurrentAmps
Real PowerWatts
Apparent PowerVAs
Reactive PowerVARs
Phase AngleDegrees
Power FactorWatts/VA
Displacement PFcos (phase angle)
Power UsagekWh, kVARh, kVAh
ACCURACYVoltage0.33% of full scale
Current1.0% of full scale w/o probe
Power1.0% of full scale w/o probe
Phase Angle1.0° w/o probe
Power Factor±0.02 w/o probe
Displacement PF±0.02 w/o probe
POWER FAIL
OPERATION
The recorder can operate without any input voltage for up to 30 minutes. This allows it to record down to 0 volts on all channels during power outages.
HARMONICSVoltageto the 51st
Currentto the 51st
MeasuresMagnitude, phase, THD
COMMUNICATIONSStandardBluetooth®2.0 Wireless, USB 2.0
OptionsMobile Phone, Wi-Fi
INFORMATION
STORAGE
Data Storage16 MB (Standard); 128 MB, 512MBor 1 GB (Optional)
Significant Change1000 records
Flicker 1000 records
RECORD
SETTINGS
Interval Graphs1 cycle to 4 hour interval, user selected, stop-when-full or wrap-around memory modes
Significant Change1V to 8V in 1V steps
Flicker SettingsUser-defined, or conform to IEEE 1453/IEC 61000-4-15, and IEEE Std. 141
Waveform CaptureVoltage and current threshold, periodic capture, waveshape, event cross triggers
Transient CapturePeak voltage threshold
POWER SUPPLY REQUIREMENTSVoltage60-600VAC Channel 1 to Common (47-63Hz)
Power Consumption5 Watts max, 15 VA max at 600V
ENVIRONMENTALOperating Temp-20°F to +135°F
HumidityLess than or equal to 85%
Shock60 Hz to 2 kHz, acceleration 25G
Vibration10Hz to 60Hz, amplitude 1.8mm
Max Altitude2.0km (6560 ft), derated above 2.0km
PHYSICAL
DIMENSIONS
Size4.8” L x 3.35” W x 1.84” H
Weightless than 1 lb
CaseNEMA 4X
SAFETYIEC 61010-1, 600V CAT IV, UL listed
VISIONPRO®
INPUTSAC Voltage0 to 600 RMS continuous per channel (±5 kV peak transients)
AC Current0 to 5000 Amps
Sample Rate1 MHz Voltage (16666 samples/cycle), 250 kHz current (4166 samples/cycle)
CHANNELSVoltage4 channels
Current4 channels
MEASURED
QUANTITIES
PER CYCLE
RMS VoltageVolts
RMS CurrentAmps
Real PowerWatts
Apparent PowerVAs
Reactive PowerVARs
Phase AngleDegrees
Power FactorWatts/VA
Displacement PFcos (phase angle)
Power UsagekWh, kVARh, kVAh
ACCURACYVoltage0.33% of full scale
Current1.0% of full scale w/o probe
Power1.0% of full scale w/o probe
Phase Angle1.0° w/o probe
Power Factor±0.02 w/o probe
Displacement PF±0.02 w/o probe
SAFETYRatingIEC 61010-1, 600V CAT IV
HARMONICSVoltageto the 51st
Currentto the 51st
Measuresmagnitude, phase, THD
COMMUNICATIONSType StandardBluetooth®2.0 Class 1 Wireless, USB 2.0, 10/100MB Ethernet
INFORMATION STORAGE Data Storage1 GB
Significant Change1000 records
Flicker 1000 records
RECORD SETTINGSInterval Graphs1 cycle/second to 4 hour interval. User selected, stop-when-full, or wrap around memory modes
Significant Change1V to 8V in 1V steps
Flicker SettingsUser-defined, or conform to IEEE 1453/IEC 61000-4-15, and IEEE Std. 141
Waveform CaptureVoltage and current threshold, periodic capture, waveshapes, event cross triggers
Transient CapturePeak voltage threshold
POWER SUPPLY Requirements Internal battery, USB charger
ENVIRONMENTALIP51 rating
PHYSICAL DIMENSIONSSize7” L X 4.5” W X 1.4” H
Weight1.2 lbs
BATTERY10 hour run-time
EAGLE® 120
INPUTSAC Voltage60 to 140 VAC, 0 to 240 VAC Peak, Neutral-Ground 0-75 VAC RMS
AC Current0 to 80 Amps RMS (15 Amps continuous)
Sample Rate256 samples/cycle/channel
CHANNELSVoltage2 channels
Current1 channel
MEASURED
QUANTITIES
PER CYCLE
RMS VoltageVolts
RMS CurrentAmps
Real PowerWatts
Apparent PowerVAs
Reactive PowerVARs
Phase AngleDegrees
Power FactorWatts/VA
Displacement PFcos (phase angle)
Power UsagekWh, kVARh, kVAh
COMMUNICATIONSTypeUSB, Bluetooth®Wireless (optional)
INFORMATION
STORAGE
Interval Graphs1.2 MB (Standard) 6.9 MB (with memory option)
Significant Change1000 records
Flicker 1000 records
Waveform Capture256 KB (standard) 1.7 MB (with memory option)
RECORD
SETTINGS
Interval Graphs1 cycle to 4 hour interval. User selected, stop-when-full, or wrap around memory modes
Significant Change1V to 8V in 1V steps
Flicker User-defined, or conform to IEEE1453/IEC61000-4-15,and IEEE Std. 141
Waveform CaptureVoltage and current threshold, periodic capture
ENVIRONMENTALOperating Temp-20°F to +135°F
Shock60 Hz to 2 kHz, acceleration 25G
Vibration10Hz to 60Hz, amplitude 1.8mm
ACCURACYVoltage0.33% of full scale
Current1.0% of full scale
Power1.0% of full scale
Phase Angle1.0°
Power Factor±0.02
Displacement PF±0.02
PHYSICAL
DIMENSIONS
Size4.9” L x 2.7” W x 1.25” H
Weight0.5 lbs
HARMONICSVoltageto the 51st
Currentto the 51st
Measuresmagnitude, phase, THD
ULTRA SLIM FLEX CTs
ELECTRICAL SPECIFICATIONS Switchable Ranges 1 to 100A, 1 to 1000A, 1 to 5000A
Operating Limit 1 to 5000A
Controls Range is chosen from the recorder, PC, or PDA software.
Power Source Power is supplied by connection to PMI recorder. No external battery or other power source is required.
Linearity ±0.05%
Phase Shift ≤±0.5% at 50 to 60 Hz
Frequency Range 8Hz to 10kHz
Crest Factor (mid range) 100A and 1000A scale: 3.0 5000A scale: 1.6
Position Sensitivity ±1.5% 1 in from connector
WORKING VOLTAGE Sensor 600V AC to earth
Module 600V AC to earth
ACCURACY ± 1% of full scale
SAFETY Double Insulated
Sensor 600V CAT IV
Module 600V CAT III
Pollution Degree 2
PMI RECORDER CAPABILITY iVS-3/600E may require a firmware upgrade
ELECTRICAL SPECIFICATIONS Switchable Ranges 1 to 100A, 1 to 1000A, 1 to 5000A
Operating Limit 1 to 5000A
Controls Range is chosen from the recorder, PC, or PDA software.
Power Source Power is supplied by connection to PMI recorder. No external battery or other power source is required.
Linearity ±0.05%
Phase Shift ≤±0.5% at 50 to 60 Hz
Frequency Range 8Hz to 10kHz
Crest Factor (mid range) 100A and 1000A scale: 3.0 5000A scale: 1.6
Position Sensitivity ±1.5% 1 in from connector
WORKING VOLTAGE Sensor 600V AC to earth
Module 600V AC to earth
ACCURACY ± 1% of full scale
SAFETY Double Insulated
Sensor 600V CAT IV
Module 600V CAT III
Pollution Degree 2
PMI RECORDER CAPABILITY iVS-3/600E may require a firmware upgrade
MECHANICAL MATERIALS Sensor Jacket Polyurethane UL94V0
Connector FR Polypropylene UL94V0
Cable Jacket Polyurethane UL94V0
PHYSICAL DIMENSIONS Min. Bending Radius 1 in (25.4 mm)
Sensor Diameter .310 in (7.9 mm)
Connector Diameter 1.07 in max (27.2 mm)
Sensor Output Cable Length 48 in (1.2 m)
ENVIRONMENTAL Operating Temperature -20 to 135°F (-29 to 57°C)
Altitude Operating 0 to 2000m, derated above 2000m
Case Protection Sensor and Module IP65 per IEC 529
PMI CT MODEL NUMBER .../12 .../24 .../36 .../48
LENGTH (OPEN) 12 in.
305 mm
24 in.
610 mm
36 in.
915 mm
48 in.
1220 mm
O.D. (CLOSED) 4.15 in.
105 mm
8.3 in.
210 mm
12 in.
305 mm
15.9 in.
404 mm
I.D. (CLOSED) 3.5 in.
89 mm
7 in.
178 mm
10.9 in.
277 mm
14.7 in.
372 mm
 
TLARs
ELECTRICAL SPECIFICATIONSCurrent Ranges20A, 200A AC
Operating Limit200A Continuous
Frequency Range40 to 10kHz
Working Voltage600 VAC max
Influence of conductor position in jaw0.5% of reading at 50/60Hz
Influence of adjacent conductor1.50%
Influence of frequency40Hz to 1kHz: 3% of reading, 1kHz to 10kHz: 12% of reading
PHASE SHIFT1-20A≤3 degrees
20-80A≤2 degrees
80-200A≤2.5 degrees
ACCURACY20A scale1 to 20 A: 1.5% of reading ±0.1A
200A scale1.5% of reading ±0.5A
SAFETYRatingUL 61010B-1
IEC 61010-1
600V CAT III
PMI RECORDER
CAPABILITY
10A range only with iVS-3/600E and ViPs with SNs lower than 61000, otherwise adjustable 20A/200A range
ENVIRONMENTALOperating Temp14 to 131°F -10 to 55°C
Operating Relative Humidity10-35°C 85% RH
Case ProtectionProbes - IP40, Enclosure - IP65
PHYSICAL
DIMENSIONS
Maximum Conductor Size0.78 in (20 mm), bus bar 20 x 5 mm
Probes5.47 x 2.00 x 1.18 in (139 x 51 x 30 mm)
Enclosure2.36 x 1.38 x 0.67 in
WeightTLAR+200/3 - 0.75 lb TLAR+200/4 - 1.00 lb
Probe Leads4 ft, 600V rating
Output Cable9 in, 600V rating
GUARDIAN®iVS-2SX+iVS-3S
INPUTSAC Voltage0 to 150 VAC per channel0 to 140 VAC0 to 600 VACcontinuous
AC Current200 Amps RMS200 Amps RMS200 Amps RMS (Forms 12S, 14S, 15S, 16S, 17S) 25 Amps (Forms 6S, 8S, 9S)
Sample Rate256 samples/cycle/channel128 samples/cycle/channel128 samples/cycle/channel
CHANNELSVoltage2 channels2 channels2 or 3 channels, depending on form
Current2 channels2 channels2 or 3 channels, depending on form
MEASURED QUANTITIES
PER CYCLE
RMS VoltageVoltsVoltsVolts
RMS CurrentAmpsAmpsAmps
Real PowerWattsWatts (Optional)Watts
Apparent PowerVAsVAsVAs
Reactive PowerVARsVARs (Optional)VARS
Phase AngleDegreesDegrees (Optional)Degrees
Power FactorWatts/VAWatts/VA (Optional)Watts/VA
Displacement PFcos (phase angle)cos (phase angle) (Optional)cos (phase angle)
Power UsagekWh, kVARh, kVAhkWh, kVARh, kVAh (Optional)kWh, kVARh, kVAh
ACCURACYVoltage0.33% of full scale0.33% of full scale0.33% of full scale
Current1.0% of full scale1.0% of full scale1.0% of full scale
Power1.0% of full scale1.0% of full scale1.0% of full scale
Phase Angle1.0° 1.0° 1.0°
Power Factor±0.02 ±0.02 ±0.02
Displacement PF±0.02 ±0.02 ±0.02
HARMONICSVoltageto the 51stto the 31st (Optional)to the 31st
Currentto the 51stto the 31st (Optional)to the 31st
Measuresmagnitude, phase, THDmagnitude, THDmagnitude, THD
COMMUNICATIONSTypeBluetooth®Wireless, USBRS232 portRS232 port
RemoteCell modem optionn/an/a
Data Rate4,800 to 28,800 baud4,800 to 38,000 baud
INFORMATION STORAGEInterval Graphs6.9 MB2.1 MB2.1 MB
Significant Change1000 records1000 records1000 records
Flicker 1000 records1000 records1000 records
Waveform Capture1.7 MB384 KB (Optional)384 KB
RECORD
SETTINGS
Interval Graphs1 second to 4 hour interval user selected, stop-when-full, or wrap around memory modes1 second to 4 hour interval user selected, stop-when-full, or wrap around memory modesUser selected, stop-when-full, or wrap around memory modes Significant Change
Significant Change1V to 8V in 1V steps1V to 8V in 1V steps1V to 8V in 1V steps
Flicker SettingsUser-defined, or conform to IEEE 1453/IEC 61000-4-15, and IEEE Std. 141.User-defined, or conform to IEEE Std. 141.User-defined, or conform to IEEE Std. 141.
Waveform CaptureVoltage and current threshold, periodic capture(Optional) voltage and current thresholdVoltage and current threshold
POWER SUPPLY Power ConsumptionLess than 2.5 wattsLess than 2.5 wattsLess than 2.5 watts
Operating Temp-20°F to +135°F-20°F to +135°F-20°F to +135°F
Shock60 Hz to 2kHz, Acceleration 25G60 Hz to 2kHz, Acceleration 25G60 Hz to 2kHz, Acceleration 25G
PHYSICAL DIMENSIONVibration10 Hz to 60 Hz, Amplitude 1.8 mm10 Hz to 60 Hz, Amplitude 1.8 mm10 Hz to 60 Hz, Amplitude 1.8 mm
Size4.625” x 6.75”4.625” x 6.75”4.625” x 6.75”
Weight3.6 lbs3.6 lbs3.6 lbs
POWER FAIL OPERATIONCan operate without any input voltage for up to 30 minutes. This allows it to record down to 0 volts on all channels during power outages.

Software & Drivers

Firmware

Documents

Product Selector

Need Help? Call: 1.800.296.4120

 
 

Sign Up for E-mail Updates

Get the latest Power Monitors® News and Special Offers!