Features
None +0.00
8 MB +210.00
Bluetooth® +265.00

Overview

Features:

  • Lightweight (0.5 lbs.)
  • Palm Sized (4.875" L x 2.625" W x 1.25" H)
  • High-Impact ABS Plastic Case
  • Fast, Single Cycle Response
  • 1 MB memory, 8 MB Optional (battery backed)

Advanced Functionality:

  • Monitor True RMS Voltage and Current
  • IEEE 1453/IEC61000-4-15 Flicker
  • Harmonics to the 51st degree
  • Minimum/Maximum/Average Recording
  • Real/Reactive/Apparent Power Recording
  • Waveform capture

Description

The Eagle 120 has all the power of the Eagle 440 in a 120 volt receptacle. The Eagle 120 power analyzer is the easiest, most advanced diagnostic tool for detecting power quality issues originating from inside a commercial or residential building.

It’s a complete ten function plug-in receptacle power quality analyzer that monitors two channels voltage and one channel of current in single-phase applications.

When plugged into a standard 120V receptacle, it continuously detects and monitors sags, swells, flicker, RMS voltage, current, power factor, and harmonics. Additionally, the Eagle 120 captures waveforms from custom-triggered events. Real-time and monitored power quality measurements are downloaded via Bluetooth wireless communications link (optional) or USB cable.

  • Fast, single cycle response
  • Waveform capture
  • High impact case and lightweight design

Specs

INPUTSAC Voltage60 to 140 VAC, 0 to 240 VAC Peak, Neutral-Ground 0-75 VAC RMS
AC Current0 to 80 Amps RMS (15 Amps continuous)
Sample Rate256 samples/cycle/channel
CHANNELSVoltage2 channels
Current1 channel
MEASURED
QUANTITIES
PER CYCLE
RMS VoltageVolts
RMS CurrentAmps
Real PowerWatts
Apparent PowerVAs
Reactive PowerVARs
Phase AngleDegrees
Power FactorWatts/VA
Displacement PFcos (phase angle)
Power UsagekWh, kVARh, kVAh
COMMUNICATIONSTypeUSB, Bluetooth®Wireless (optional)
INFORMATION
STORAGE
Interval Graphs1.2 MB (Standard) 6.9 MB (with memory option)
Significant Change1000 records
Flicker 1000 records
Waveform Capture256 KB (standard) 1.7 MB (with memory option)
RECORD
SETTINGS
Interval Graphs1 cycle to 4 hour interval. User selected, stop-when-full, or wrap around memory modes
Significant Change1V to 8V in 1V steps
Flicker User-defined, or conform to IEEE1453/IEC61000-4-15,and IEEE Std. 141
Waveform CaptureVoltage and current threshold, periodic capture
ENVIRONMENTALOperating Temp-20°F to +135°F
Shock60 Hz to 2 kHz, acceleration 25G
Vibration10Hz to 60Hz, amplitude 1.8mm
ACCURACYVoltage0.33% of full scale
Current1.0% of full scale
Power1.0% of full scale
Phase Angle1.0°
Power Factor±0.02
Displacement PF±0.02
PHYSICAL
DIMENSIONS
Size4.9” L x 2.7” W x 1.25” H
Weight0.5 lbs
HARMONICSVoltageto the 51st
Currentto the 51st
Measuresmagnitude, phase, THD