| Base price | $6,295.00 |
| Models | |
| Vision® Pro | $9,395.00 |
| Vision® Lite | $3,195.00 |
Overview
Features:
- CAT IV 600 Volt Rating
- Up to 1 Megahertz Voltage Sampling
- Up to 5kV Transient Capture
- Up to 1 GB Internal Memory
Unrivaled Communication Options:
- USB 2.0
- Ethernet
- Bluetooth® 2.0
Description
We’ve loaded the Vision handheld power quality analyzer with features you won’t find on larger, more expensive power analyzers. The Vision combines PMI’s industry-leading wireless power quality monitoring technology with a handheld, graphical meter. Use it to view real-time waveforms, make spot measurements, and take measurement snapshots, then leave it in place for full power logging.
The Vision measures voltage, current, all power quantities, harmonics, and flicker. It includes a color graphical LCD display, data storage, and high speed USB.
- True RMS voltage and current measurement
- User-programmable waveform and transient capture
- Real-time graphical display of voltage and current waveforms, power, vectors, harmonics
- Viewing of all real-time data without disturbing or altering an in-progress power monitoring session
- 16,666 samples per 60Hz cycle per voltage channel (VisionPro)
- 4,166 samples per 60Hz cycle per current channel (VisionPro)
- 0-600 Vrms (continuous) measurement, ±5kV peak transient capture
- 20 and 200A current range TLAR clamps; 100, 1000, and 5000A current range FlexCTs
- Up to 1GB memory
- Individual factory calibration and report ensures high accuracy and stability over a wide temperature range.
Accessories (Included)
- Flex 12/4 four-channel flexible current probes
- Voltage leads
- Soft Carrying Case
- Communication Cables: USB, Ethernet* * Vision Pro only
Specs
| VISIONLITE® | VISION® | VISIONPRO® | ||
| INPUTS | AC Voltage | 0 to 600 RMS continuous per channel | 0 to 600 RMS continuous per channel | 0 to 600 RMS continuous per channel (±5 kV peak transients) |
| AC Current | 0 to 5000 Amps | 0 to 5000 Amps | 0 to 5000 Amps | |
| Sample Rate | 15,360 samples per second/channel; 256 samples per cycle | 15,360 samples per second/channel; 256 samples per cycle | 1 MHz Voltage (16666 samples/cycle), 250 kHz current (4166 samples/cycle) | |
| CHANNELS | Voltage | 3 channels | 4 channels | 4 channels |
| Current | 3 channels | 4 channels | 4 channels | |
| MEASURED QUANTITIES PER CYCLE | RMS Voltage | Volts | Volts | Volts |
| RMS Current | Amps | Amps | Amps | |
| Real Power | Watts | Watts | Watts | |
| Apparent Power | VAs | VAs | VAs | |
| Reactive Power | VARs | VARs | VARs | |
| Phase Angle | Degrees | Degrees | Degrees | |
| Power Factor | Watts/VA | Watts/VA | Watts/VA | |
| Displacement PF | cos (phase angle) | cos (phase angle) | cos (phase angle) | |
| Power Usage | kWh, kVARh, kVAh | kWh, kVARh, kVAh | kWh, kVARh, kVAh | |
| ACCURACY | Voltage | 0.33% of full scale | 0.33% of full scale | 0.33% of full scale |
| Current | 1.0% of full scale w/o probe | 1.0% of full scale w/o probe | 1.0% of full scale w/o probe | |
| Power | 1.0% of full scale w/o probe | 1.0% of full scale w/o probe | 1.0% of full scale w/o probe | |
| Phase Angle | 1.0° w/o probe | 1.0° w/o probe | 1.0° w/o probe | |
| Power Factor | ±0.02 w/o probe | ±0.02 w/o probe | ±0.02 w/o probe | |
| Displacement PF | ±0.02 w/o probe | ±0.02 w/o probe | ±0.02 w/o probe | |
| SAFETY | Rating | IEC 61010-1, 600V CAT IV | IEC 61010-1, 600V CAT IV | IEC 61010-1, 600V CAT IV |
| HARMONICS | Voltage | to the 51st | to the 51st | to the 51st |
| Current | to the 51st | to the 51st | to the 51st | |
| Measures | magnitude, phase, THD | magnitude, phase, THD | magnitude, phase, THD | |
| COMMUNICATIONS | Type Standard | USB 2.0 | Bluetooth®2.0 Class 1Wireless, USB 2.0 | Bluetooth®2.0 Class 1 Wireless, USB 2.0, 10/100MB Ethernet |
| INFORMATION STORAGE | Data Storage | 1 MB | 16 MB | 1 GB |
| Significant Change | 500 records | 1000 records | 1000 records | |
| Flicker | 500 records | 1000 records | 1000 records | |
| RECORD SETTINGS | Interval Graphs | 1 second to 4 hour interval. User selected, stop-when-full, or wrap around memory modes. | 1 cycle/second to 4 hour interval. User selected, stop-when-full, or wrap around memory modes | 1 cycle/second to 4 hour interval. User selected, stop-when-full, or wrap around memory modes |
| Significant Change | 1V to 8V in 1V steps | 1V to 8V in 1V steps | 1V to 8V in 1V steps | |
| Flicker Settings | User-defined, or conform to IEEE 1453/IEC 61000-4-15, and IEEE Std. 141 | User-defined, or conform to IEEE 1453/IEC 61000-4-15, and IEEE Std. 141 | User-defined, or conform to IEEE 1453/IEC 61000-4-15, and IEEE Std. 141 | |
| Waveform Capture | Voltage and current threshold, periodic capture, waveshapes, event cross triggers | Voltage and current threshold, periodic capture waveshapes, event cross triggers | Voltage and current threshold, periodic capture, waveshapes, event cross triggers | |
| Transient Capture | N/A | N/A | Peak voltage threshold | |
| POWER SUPPLY | Requirements | Internal battery, USB charger | Internal battery, USB charger | Internal battery, USB charger |
| ENVIRONMENTAL | IP51 rating | IP51 rating | IP51 rating | |
| PHYSICAL DIMENSIONS | Size | 7” L X 4.5” W X 1.4” H | 7” L X 4.5” W X 1.4” H | 7” L X 4.5” W X 1.4” H |
| Weight | 1.2 lbs | 1.2 lbs | 1.2 lbs | |
| BATTERY | 5 hour run-time | 10 hour run-time | 10 hour run-time | |